<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://bcmeter.org/wiki/index.php?action=history&amp;feed=atom&amp;title=Best_practices</id>
	<title>Best practices - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://bcmeter.org/wiki/index.php?action=history&amp;feed=atom&amp;title=Best_practices"/>
	<link rel="alternate" type="text/html" href="https://bcmeter.org/wiki/index.php?title=Best_practices&amp;action=history"/>
	<updated>2026-05-15T09:24:08Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.36.0</generator>
	<entry>
		<id>https://bcmeter.org/wiki/index.php?title=Best_practices&amp;diff=300&amp;oldid=prev</id>
		<title>Bcmwiki: Wiki update: sync with manual and dev docs (2026-03)</title>
		<link rel="alternate" type="text/html" href="https://bcmeter.org/wiki/index.php?title=Best_practices&amp;diff=300&amp;oldid=prev"/>
		<updated>2026-03-08T13:10:10Z</updated>

		<summary type="html">&lt;p&gt;Wiki update: sync with manual and dev docs (2026-03)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Best Practices ==&lt;br /&gt;
&lt;br /&gt;
=== Environment ===&lt;br /&gt;
&lt;br /&gt;
* Keep the device &amp;#039;&amp;#039;&amp;#039;away from direct sunlight&amp;#039;&amp;#039;&amp;#039;, radiators, and fireplaces — it is sensitive to temperature and lighting changes.&lt;br /&gt;
* Position the inlet away from localized emission sources unless intentionally measuring them.&lt;br /&gt;
* For indoor use, avoid placement near HVAC vents or drafts.&lt;br /&gt;
&lt;br /&gt;
=== Sampling Configuration ===&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Sample frequency:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** Ambient immission monitoring: &amp;#039;&amp;#039;&amp;#039;180–600 seconds&amp;#039;&amp;#039;&amp;#039; (3–10 min)&lt;br /&gt;
** Direct emissions from wood stoves (µg vs ng range): &amp;#039;&amp;#039;&amp;#039;10–30 seconds&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** Note: increasing frequency may increase noise.&lt;br /&gt;
&lt;br /&gt;
* &amp;#039;&amp;#039;&amp;#039;Airflow:&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
** Minimum 40 mL/min, maximum 400 mL/min (hardware-dependent).&lt;br /&gt;
** Higher airflow improves signal strength but loads the filter faster.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Pollution Level !! Daily Avg BC !! Recommended Airflow&lt;br /&gt;
|-&lt;br /&gt;
| Heavy pollution || &amp;gt;2000 ng/m³ || 50 mL/min&lt;br /&gt;
|-&lt;br /&gt;
| Typical urban || ~500 ng/m³ || 100–250 mL/min&lt;br /&gt;
|-&lt;br /&gt;
| Low pollution || &amp;lt;500 ng/m³ || 300–400 mL/min&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
When &amp;#039;&amp;#039;&amp;#039;Auto Flow Control&amp;#039;&amp;#039;&amp;#039; is enabled, the device adjusts airflow automatically based on measured BC concentration — reducing flow when BC is high (to extend filter life) and increasing flow when BC is low (for better signal).&lt;br /&gt;
&lt;br /&gt;
=== Signal Quality ===&lt;br /&gt;
&lt;br /&gt;
Signal-to-noise ratio improves with:&lt;br /&gt;
* Higher BC loads&lt;br /&gt;
* Higher air volume per sample&lt;br /&gt;
* Smaller sample spot diameter&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Filtering:&amp;#039;&amp;#039;&amp;#039; Apply median/average filtering (denoise slider) to reduce noise. The rolling average is closer to the &amp;quot;real&amp;quot; value than individual data points.&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Calibration:&amp;#039;&amp;#039;&amp;#039; Always calibrate after every filter change for reliable filter status indication and accurate measurement.&lt;br /&gt;
&lt;br /&gt;
=== Filter Management ===&lt;br /&gt;
&lt;br /&gt;
* At the default airflow in a typical urban environment (~500 ng/m³), a filter lasts approximately &amp;#039;&amp;#039;&amp;#039;3–5 days&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
* In heavily polluted areas, a filter may saturate in &amp;#039;&amp;#039;&amp;#039;6–12 hours&amp;#039;&amp;#039;&amp;#039;.&lt;br /&gt;
* The filter is considered saturated at approximately &amp;#039;&amp;#039;&amp;#039;30% attenuation&amp;#039;&amp;#039;&amp;#039;. Beyond this, accuracy degrades — values are flagged in the CSV.&lt;br /&gt;
* The [[Configuration#Measurement Tab|Airflow Reference table]] in Settings helps estimate filter lifetime for your conditions.&lt;br /&gt;
&lt;br /&gt;
=== Supported Filter Papers ===&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Filter Paper !! Scattering Correction Factor&lt;br /&gt;
|-&lt;br /&gt;
| Pall T60A20 || 1.0&lt;br /&gt;
|-&lt;br /&gt;
| AE33 Filter || 0.75&lt;br /&gt;
|-&lt;br /&gt;
| AE51 Filter || 1.0&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Other filter papers can be supported by determining their scattering factor. Send a sample to jd@bcmeter.org for calibration.&lt;/div&gt;</summary>